Set up a data source

Publish OPC-UA Variables using PLC Designer

Share variables via OPC UA protocol Open the project in PLC Designer Make sure that the selected controller supports OPC UA protocol by going to Device → Log (Currently supported Lenze controllers: 3200C, p500, c300, p300, C5x0, c750 ): Right click Application in the Devices window, then select Add Object.. → Symbol Configuration: Tick off …

Publish OPC-UA Variables using PLC Designer Read More »

Import variables: CSV file structure

The import function in the data source configurator is, together with the export function, built to easily and effortlessly copy variables from one device to another. Additionally, you can use the import function to prepare variables in a CSV file and load them all at once into your configurator. This article explains the structure of the CSV file and the syntax of …

Import variables: CSV file structure Read More »

BACnet/IP

The first step in Cloud Logging is setting up a data source. This is done by selecting a communication protocol and defining the variables. This article shows you how to do this for communication via BACnet/IP. Select a communication protocol Add variables (new, import) Test variables Manage variables (export, duplicate, remove) Select the communication protocol “BACnet/IP“. The port number will automatically …

BACnet/IP Read More »

Ethernet/IP

The first step in Cloud Logging is setting up a data source. This is done by selecting a communication protocol and defining the variables. This article shows you how to do this for communication via Ethernet/IP. PLC settings Select a communication protocol Available datatypes Add variables (new, import) Test variables Manage variables (export, duplicate, remove) PLC setting Allen-Bradley devicesEvery …

Ethernet/IP Read More »

Modbus TCP/IP

The first step in Cloud Logging is setting up a data source. This is done by selecting a communication protocol and defining the variables. This article shows you how to do this for communication via Modbus TCP/IP. Select a communication protocol Add variables (new, import) Test variables Manage variables (export, duplicate, remove) Select the communication protocol “Modbus“. The port number, slave …

Modbus TCP/IP Read More »

OPC-UA

The first step in Cloud Logging is setting up a data source. This is done by selecting a communication protocol and defining the variables. This article shows you how to do this for communication via OPC-UA. PLC settings Select a communication protocol Available datatypes Add variables (new, import) Test variables Manage variables (export, duplicate, remove) PLC setting On some …

OPC-UA Read More »

Siemens S7

The first step in Cloud Logging is setting up a data source. This is done by selecting a communication protocol and defining the variables. This article shows you how to do this for a Siemens S7-300/400/1200/1500 PLC. PLC settings Select a communication protocol Available datatypes Add variables (new, import) Test variables Manage variables (export, duplicate, remove) PLC settings The S7-1200 and S7-1500 PLCs …

Siemens S7 Read More »